The reason why the amplitude of the ultrasonic vibrating screen is small

The reasons for the small amplitude of the ultrasonic vibrating screen are:

Screen, resonance, ultrasonic screening system cable connection, ultrasonic transducer

1. Screen: The ultrasonic vibrating screen is not tightened when the net is installed or the screen is opened to make the amplitude smaller.

2. Resonance: The vibration motor or the screen frame is damaged or cracked, causing the frequency offset to make the amplitude small.

3. Ultrasonic screening system cable: Ultrasonic screening system is an important screening system for ultrasonic vibrating screen. The cable connecting the ultrasonic power supply and the transducer is a cable. If the cable insulation measures are not done well, the amplitude will be reduced. .

4. ultrasonic transducer: If the ultrasonic grid and the transducer are not locked, the amplitude will be reduced.

Ultrasonic vibrating screen with small amplitude solution:

1. Screen problem: You can check whether the screen is tight and open by hand. If it is found that there is no tension or glue opening, the screen should be removed from the new stretch net.

2, resonance problem: you can check the motor or screen frame, if the crack is found, immediately stop the machine and contact the manufacturer for maintenance.

3. Connection cable problem: You can check the insulation value of the cable and plug and find out the problem in time.

4, the transducer problem: you can carefully check the contact between the grid and the transducer, if you find that the foreign matter is thoroughly cleaned.